Home | Summary
SUMMARY
ROLLESTON COAL - GLENCORE REACTIVITY TEST NOVEMBER 2022 | GC17-11-22
Download Report
Results:
Table 1 Results for Testing using QMR Reactive Ground Test
Table 2 Results for Testing using AEISG Code of Practice
Prior to testing as per the AEISG Code of Practice each sample was assessed for reactivity risk based on pH, carbonate and the amount of reactive sulphide and coal using the QMR Reactive Ground Test (refer to Table 1 and Table 2 for results of both tests). Three samples contained more than trace sulphide with Sample C123-97_ER01 the only sample containing more than 1% sulphide. Sample C123-97_ER01 was inhibited by the 2coal which inhibited a reaction between the sulphide and nitrate when tested as per the AEISG Code of Practice
Conclusion:
All samples were found not to be reactive when tested as per the AEISG Code of Practice and the QMR Reactive Ground Test.
Date:
14th November 2022
Data Files:
AEISG Temperature Logs:
Data34.xlsx
QMR Reactive Ground Test results tables and audited temperature logs:
QMRTestResults.xlxs
Templog42.xlxs
Templog44.xlxs