Sentry Page Protection

Home | Summary | Samples

MCARTHUR RIVER MINE | SEPTEMBER 2020

SAMPLES

Table 5 - Testing of the 3 most reactive samples as per the AEISG Code of Practice for testing of inhibited products at elevated of  temperature of 90°C for 28 Days


RG_20200725_003 + 50% Rioflex MX/50% prilled Ammonium Nitrate

Sample RG20200725_003 +  50% Rioflex MX/50% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_003 +  60% Rioflex MX/40% prilled Ammonium Nitrate

Sample RG20200725_003 +  60% Rioflex MX/40% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_003 +  70% Rioflex MX/30% prilled Ammonium Nitrate

Sample RG20200725_003 +  70% Rioflex MX/30% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_004 + 50% Rioflex MX/50% prilled Ammonium Nitrate

Sample RG20200725_004 +  50% Rioflex MX/50% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_004 +  60% Rioflex MX/40% prilled Ammonium Nitrate

Sample RG20200725_004 +  60% Rioflex MX/40% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_004 +  70% Rioflex MX/30% prilled Ammonium Nitrate

Sample RG20200725_004 +  70% Rioflex MX/30% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_005 + 50% Rioflex MX/50% prilled Ammonium Nitrate

Sample RG20200725_005 +  50% Rioflex MX/50% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_005 +  60% Rioflex MX/40% prilled Ammonium Nitrate

Sample RG20200725_005 +  60% Rioflex MX/40% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx


RG20200725_005 + 70% Rioflex MX/30% prilled Ammonium Nitrate

Sample RG20200725_005 +  70% Rioflex MX/30% prilled Ammonium Nitrate temperature plot and pictures of sample after test showing no signs of a reaction or visible NOx