Sentry Page Protection

 Home | Summary

SUMMARY

HVO REACTIVITY TEST december 2022 | QMR18-12-22

Download Report


Table 1 - Results for Testing using the AEISG Code of Practice


Table 2 - Results for Testing using the QMR Reactive Ground Test

Prior to testing as per the AEISG Code of Practice each sample was assessed for reactivity risk based on pH, carbonate and amount of reactive sulphide  using the QMR Reactive Ground Test (refer to Table 1  and Table 2  for results of both tests).  The pH of the samples was low which increases the risk of reactivity.  Two samples contained sulpide levels of >4. % and one of these samples contain 16% coal which inhibits the reaction.


Conclusion:

The following samples are reactive as per the AEISG Code of practice:

  • 5324C_RG12

  • 5340C_RG04

The following samples are marginal as per the AEISG Code of practice:

  • 5324C_RG16

  • 5340C_RG01

  • 5340C_RG02

  • 5340C_RG12

All other samples tested as not reactive.

References:

  • QMR Reactive Ground Test: rga57.csv, rga58.csv, templog48.csv and templog49.csv

  • AEISG Test: 5340C_RG04, AEISGdata36.xlxs and AEISGT2.xlxs

  • Tables RGA57.xlxs

Assessed By:

Dr G. Cavanough

Date:

8th December 2022

Member Login