ACARP Project C35018 Reactive Ground Testing.
Rolleston samples of confidential data.

Testing of samples using AEISG code testing for reactivity over a period of 7 days.

Conducted For: Rolleston Coal - GLENCORE

Requested By: Nicole Phillips

Report No.: QMR19-08-23


Results:                          

Table 1 Received samples

Each sample was assessed for reactivity risk based on pH, carbonate content, reactive sulphide content and coal content using the QMR Reactive Ground Test (refer to Table 2). One sample that was tested had a reactive sulphide content above trace. This sample was alkaline and contained coal which inhibited a reaction with nitrates. 


Table 2 Results for Testing


Conclusion:

All samples were found to be not reactive.

Assessed By:

Dr G. Cavanough

Date:

18th August 2023