Sentry Page Protection

Home | Summary

Reactivity Test Report - Summary

Project: Testing of Samples using AEISG code testing for reactivity over a period of 7 days.

Conducted For: Rolleston Coal - GLENCORE

Requested By: Nicole Phillips

Report No.: QMRreport01-01-23

Download Report


Results:                          

Table 1 Results for Testing using QMR Reactive Ground Test


Table 2 Results for Testing using AEISG Code of Practice


Prior to  testing as per the AEISG Code of Practice each sample was assessed for reactivity risk based on pH, carbonate and the amount of reactive sulphide  and coal using the QMR Reactive Ground Test (refer to Table 1 and Table 2 for results of both tests). Only sample C13101_RG06  contained more than trace sulphide which was inhibited by the 17% coal content. 

Conclusion:

All samples were found not to be reactive when tested as per the AEISG Code of Practice and the QMR Reactive Ground Test.      

Assessed By:                               

Dr G. Cavanough 

Date:                          

3rd January 2023

Data Files:

AEISG Temperature Logs:

  • Data37AEISGTest.xlsx

QMR Reactive Ground Test results tables and audited temperature logs:

  • QMRTest.xlxs

  • Rga60.xlxs

  • Templog51.xlxs