Sentry Page Protection

 Home | Summary

Reactivity Test Report

ROLLESTON COAL - GLENCORE REACTIVITY TEST november 2024 | QMR11-11-24A

Testing of samples using AEISG code testing for reactivity over a period of 7 days.


Samples Tested from Batch Received


Results:

Table 1 -AEISG Test Results


Table 2 - QMR Test Results


Each sample was assessed for reactivity risk based on pH, carbonate content, reactive sulphide content and coal content using the QMR Reactive Ground Test. Four samples have more than 1% reactive sulphide with a maximum reacive sulphide of 2.3%. These low levels of reactive sulphide will produce limited heat energy should a reaction occur. All samples are alkaline inhibiting a reaction when tested as per the AEISG Code of Practice.

Conclusion:

All samples were found to be not reactive when tested as per the AEISG Code of Practice and the QMR Test.

Assessed By:

Dr G. Cavanough

Date:

18th November 2024

References:

• Test data files: rga50.xlxs, templog48.csv, data26a.csv, data24batch1.xlxs and 105Samples_to 16th November.xlsx