Reactivity Test Report

ROLLESTON COAL - GLENCORE REACTIVITY TEST DECEMBER 2024 | QMR181224

Testing of samples using AEISG code testing for reactivity over a period of 7 days.

Download Report


Table 1 - AEISG Test Results

*Figure 1 - MW050_TP2_ER01, MW050_TP3_ER01 and MW050_TP4_ER02 physically reacted so are classified as reactive at per the AEISG Code of Practice


Table 2 - QMR Test Results

Each sample was assessed for reactivity risk based on pH,  carbonate content, reactive sulphide content and coal content using the QMR Reactive Ground Test.  Ten samples contained ≥1% reactive sulphide as described  in Table 3.


Table 3 – Samples with ≥1% Reactive Sulphide


Conclusion:

All samples were found to be not reactive when tested as per the AEISG Code of Practice and the QMR Test apart from:

• MW050_TP2_ER01 pH5.5 and 8% reactive sulphide content QMR and AEISG Reactive

• MW050_TP3_ER01 pH 6 and 2.1% reactive sulphide physical reaction therefore AEISG reactive

• MW050_TP4_ER01 physical reaction therefore AEISG reactive

• MW050_TP3_ER01 1.2°C therefore AEISG Marginal.

Assessed By:

Dr G. Cavanough

Date:

20th December 2024