HVO REACTIVITY TEST JULY 2022 | QMR09-07-22

Download Report


Results

Two reactive samples, “RG_WN47LEB024_003coal” and “RG_WEST49LAU_009” were selected to use for the inhibited product test as described in Report GC17-05-22. These sample were used to test the 3 blends as described in Table 1.

Table 1 - Blends Tested as per AEISG Code of Practice for Testing Inhibited Products

Table 1 - Blends Tested as per AEISG Code of Practice for Testing Inhibited Products

Gassers was also added to each sample before adding the reactive sample and the  weathering agent.  The samples were tested over a period of 28 days and no temperature Isotherms were recorded (refer to Table 1 and Figure 1). 


Table 2 - Results for Testing using AEISG Code of Practice for Inhibited Product Testing


Figure 1 -AEISG Temperature graph of all samples showing no rise in temperature for any sample


Conclusion:

Bulk explosive products S371, S330 and S364 inhibited any reactions with samples “RG_WN47LEB024_003coal” and “RG_WEST49LAU_009” when tested as per the AEISG Code of Practice for testing of inhibited products.

Assessed By:                         

Dr G. Cavanough 

Date:                          

29th August 2022