Sentry Page Protection

Home | Summary | Samples

KARORA RESOURCES -HIGGINSVILLE OPERATIONS – SPARGOS REWARD PROJECT - FEBRUARY 2022 samples


Karora F1

Temperature plot and picture of sample after test showing small temperature rise (≈1.3°C) on initial heating due to 0.3% reactive sulphide, pH of 6 and carbonates.


Karora F2

Temperature plot and picture of sample after test showing small temperature rise (≈2.1°C) on initial heating due to 0.36% reactive sulphide, pH of 6 and no carbonates.


Karora F3

Temperature plot and picture of sample after test showing small temperature rise (≈2.5°C) on initial heating due to 0.36% reactive sulphide, pH of 6 and no carbonates.


Karora f4

Temperature plot and picture of sample after test showing no temperature rise due to no reactive sulphide, pH of 7 and no carbonates.


Karora S1

Temperature plot and picture of sample after test showing large temperature rise on initial heating (≈155°C) due to >10% reactive sulphide, pH of 5 and no carbonates.


Karora S2

Temperature plot of sample after test showing rapid temperature rise on initial heating due to >10% reactive sulphide, pH of 4.5 and no carbonates.


Karora S3

Temperature plot and picture of sample after test showing large temperature rise (≈155°C) on initial heating(≈295°C)  due to >10% reactive sulphide, pH of 5 and no carbonates.


karora s4

Temperature plot and picture of sample after test showing no temperature rise due to 0.92% reactive sulphide, pH of 6 and high carbonates.


Karora s4 drill cuttings

Temperature plot and picture of sample after test showing large temperature rise (≈155°C) on initial heating due to >10% reactive sulphide, pH of 4 and no carbonates.


Karora w1

Temperature plot and picture of sample after test showing no temperature rise due to 0.4% reactive sulphide, pH of 9 and no carbonates.


karora w2

Temperature plot and picture of sample after test showing no temperature rise due to 0.37% reactive sulphide, pH of 9 and no carbonates.


Karora w3

Temperature plot and picture of sample after test showing small temperature rise (≈23°C) on initial heating due to 2.75% reactive sulphide, pH of 5 and no carbonates.


Karora w4

Temperature plot and picture of sample after test showing no temperature rise due to 0.42% reactive sulphide, pH of 8 and no carbonates.