Test 1: Reactivity Screening of LPH 7 NE Sample
- NO REACTION TO CLASS AS REACTIVE
- Lab grade AN -35 days duration at 55°C
View fullsize

Test 1- Lab Grade AN + LPH 7 NE – no temperature rise above 2C° over a period of 7 days
View fullsize

Test 1- Lab Grade AN + LPH 7 NE - Low Levels of NOx visible after 35 days indicating a low level reaction between sulphide and nitrate
Test 2. Reactivity Screening of LPH 7 NE Sample with Carbonates Removed
- SPONTANEOUS REACTION
- Lab grade AN -20 minutes duration at 55°
View fullsize

Test 2- Lab Grade AN + LPH 7 NE with carbonates removed – rapid temperature rise over 20 minutes
View fullsize

Test 2- Lab Grade AN + LPH 7 NE with carbonates removed under test– NOx gas from first contact with AN indicating highly reactive
View fullsize

LPH 7 NE Sample after carbonates removed showing fine particles of Sulphide
Test 3. Inhibited Product Testing of LPH 7 NE Sample with Carbonates removed
- NO REACTION
- 60% Rioflex MX / 40% Prill Blend -28 days at 55°C
View fullsize

Test 3- 60% Rioflex MX / 40% Prill Blend + LPH 7 NE with carbonates removed – no temperature rise over 28 days
View fullsize

Test 3 - 60% Rioflex MX / 40% Prill Blend + LPH 7 NE with carbonates removed - no NOx visible after 28 days indicating no reaction between sulphide and nitrate.
Test 4. Inhibited Product Testing of LPH 7 NE
- NO REACTION
View fullsize

Test 4 - 60% Rioflex MX / 40% Prill Blend + LPH 7 NE – no temperature rise over 28 days
View fullsize

Test 4 - 70% Rioflex MX 30% Prill Blend + LPH 7 NE – no temperature rise over 28 days
View fullsize

Test 4 - Rioflex MX 60%/40% Prill Blend + LPH 7 NE and Rioflex MX 70%/30% Prill Blend + Waste - no NOx visible after 28 days indicating no reaction between sulphide and nitrate.
Test 4. Lab. Grade wAN with LPH 7 NE Sample at 90°C
- REACTIVE
View fullsize

Test 4 – Lab. Grade AN + LPH 7 NE – small temperature isotherm on heating
View fullsize

Test 4 – Lab. Grade AN + LPH 7 NE - visible signs of reaction
View fullsize

Test 4 – Lab. Grade AN + LPH 7 NE - recovered melted thermocouples